<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15183</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: remove plate not fully on unload table
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
With this error pending, read the unload plate sensor using "picker"
or "sat stat pkr".
</text></DescriptionText>
<DescriptionText><text>
Check unload sensor and cable.
</text></DescriptionText>
<DescriptionText><text>
Look for plate skew during unload. Check unload vacuum threshold, set up
using "cal uvac"
</text></DescriptionText>
<DescriptionText><text>
Check unload sucction cups for damage.
</text></DescriptionText>
<DescriptionText><text>
Run "time table", check that the unload cylinder is moving properly.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
<DescriptionText><text>
Resume.  If this fails then lift the bridge and secure,  open the front
panel and remove the plate, then select clear.
</text></DescriptionText>
</OperatorAction>
<Cause>
During an unload, once the unload cylinder is retracted, a further period of
sensor_delay is allwed for the upper unload plate sensor to detect the plate and
the lower one to not-detect the plate (if enabled), else this error is reported.
</Cause>
<Cause>
Before the process command is executed the process status is checked and if there is a
plate sensed on the Lower unload sensor, then this error is reported.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_nups.xml</LinkAddress><LinkTitle>NVS: al nups</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldly_cal_sensor.xml</LinkAddress><LinkTitle>NVS: aldly sensor</LinkTitle></Link>
<Link><LinkAddress>../commands/table.xml</LinkAddress><LinkTitle>Command: table</LinkTitle></Link>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
<Link><LinkAddress>../commands/cal.xml</LinkAddress><LinkTitle>Command: cal</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:55 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/platesetter_3244/content/troubleshooting/15183.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>